Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Gynecol Oncol ; 179: 33-41, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37913639

RESUMO

AIMS: The aim of this study was to provide a literature review on the efficacy and safety of reirradiation(re-I) of locoregional recurrences in gynecological malignancies. METHODS: A computerized literature search was performed in 4 electronic databases (1993-2020). Random-effects models and a tendency towards high heterogeneity (Cochran Q chi-square test and the I2 statistic) were used. A meta-analysis technique over single and multi-arm studies was performed to determine the pooled acute and late toxicity rate ≥ G3, locoregional control (LC), and overall survival (OS). RESULTS: Out of 178 articles, only 18 articles accounting for 820 patients (pts) met the inclusion criteria. Outcomes were evaluable for 522 patients. Subgroup analyses highlighted moderate to high heterogeneity among studies. BT (Brachytherapy) showed a 2y OS of 63% (95% CI, 55 to 71 p = 0,36) and 5y OS of 42% (95% CI, 35 to 50, p = 0,43) with 1y-2y-3y LC of 74 (95% CI, 62 to 75, p = 0.04)49% (95% CI, 40 to 58, p = 0.38) and 48% (95% CI, 39 to 58, p = 0,45) respectively. Chemotherapy does not improve SBRT outcomes: BT showed a G3- G4 toxicities rate was of26% (95% CI: 8-49%); studies on SBRT re-I showed a G3-G4 toxicity around of 20% if combined with CHT, and <10 when alone. CONCLUSION: A large heterogeneity among studies was revealed, but showing promising results in terms of safety and feasibility. BT resulted the best kind of radiation therapy delivery in terms of clinical outcome and comparable to the SBRT technique in terms of toxicities.


Assuntos
Neoplasias dos Genitais Femininos , Reirradiação , Humanos , Feminino , Reirradiação/efeitos adversos , Reirradiação/métodos , Neoplasias dos Genitais Femininos/radioterapia , Recidiva Local de Neoplasia/patologia , Oncologia , Itália
2.
Radiol Med ; 128(7): 877-885, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37294366

RESUMO

PURPOSE: To evaluate the role of stereotactic body radiation therapy (SBRT) delivered after external-beam fractionated irradiation in non-small-cell lung cancer (NSCLC) patients with clinical stage III A, B. MATERIALS AND METHODS: All patients received three-dimensional conformal radiotherapy (3D-CRT) or intensity modulated radiation therapy (IMRT) (60-66 Gy/30-33 fractions of 2 Gy/5 days a week) with or without concomitant chemotherapy. Within 60 days from the end of irradiation, a SBRT boost (12-22 Gy in 1-3 fractions) was delivered on the residual disease. RESULTS: Here we report the mature results of 23 patients homogeneously treated and followed up for a median time of 5.35 years (range 4.16-10.16). The rate of overall clinical response after external beam and stereotactic boost was 100%. No treatment-related mortality was recorded. Radiation-related acute toxicities with a grade ≥ 2 were observed in 6/23 patients (26.1%): 4/23 (17.4%) had esophagitis with mild esophageal pain (G2); in 2/23 (8.7%) clinical radiation pneumonitis G2 was observed. Lung fibrosis (20/23 patients, 86.95%) represented a typical late tissue damage, which was symptomatic in one patient. Median disease-free survival (DFS) and overall survival (OS) were 27.8 (95% CI, 4.2-51.3) and 56.7 months (95% CI, 34.9-78.5), respectively. Median local progression-free survival (PFS) was 17 months (range 11.6-22.4), with a median distant PFS of 18 months (range 9.6-26.4). The 5-year actuarial DFS and OS rates were 28.7% and 35.2%, respectively. CONCLUSIONS: We confirm that a stereotactic boost after radical irradiation is feasible in stage III NSCLC patients. All fit patients who have no indication to adjuvant immunotherapy and presenting residual disease after curative irradiation could benefit from stereotactic boost because outcomes seem to be better than might be historically assumed.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Lesões por Radiação , Radiocirurgia , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Neoplasias Pulmonares/tratamento farmacológico , Radioterapia de Intensidade Modulada/métodos , Etoposídeo/uso terapêutico
3.
In Vivo ; 35(1): 571-578, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33402511

RESUMO

BACKGROUND/AIM: To evaluate the impact of sarcopenia in muscle invasive bladder cancer (MIBC) elderly patients submitted to curative radiotherapy. PATIENTS AND METHODS: Patients received radiotherapy between 2013 and 2018, and the skeletal muscle index was calculated to classify them as sarcopenic or non-sarcopenic. Primary endpoints were overall survival (OS), cancer specific survival (CSS), 90-day mortality and toxicity. RESULTS: A total of 28 patients with a median age of 85 years met our inclusion criteria and 8 of them were sarcopenic. With a median prescribed dose of 61 Gy and a median follow-up of 24.5 months, OS rates in the sarcopenic and non-sarcopenic groups were 100% and 84.4% at 3 months, 57.1% and 56.6% at 12 months, 38.1% and 50.3% at 24 months and 38.1% and 33.5% at 48 months, respectively; the CSS rates were 100% and 94.1% at 3 months and 68.6% and 88.2% at 12, 24 and 48 months, respectively. The actuarial 90-day mortality rate was 17.9% for the whole cohort, and 20% and 12.5% for the non-sarcopenic and sarcopenic groups, respectively. The radio-induced toxicity was similar in both groups. CONCLUSION: Sarcopenia cannot be considered a negative prognostic factor for MIBC elderly patients treated with external beam radiotherapy. Irradiation is therefore a feasible and effective choice for these patients, especially if unfit for surgery.


Assuntos
Sarcopenia , Neoplasias da Bexiga Urinária , Idoso , Idoso de 80 Anos ou mais , Humanos , Músculo Esquelético/patologia , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida , Neoplasias da Bexiga Urinária/complicações , Neoplasias da Bexiga Urinária/patologia , Neoplasias da Bexiga Urinária/radioterapia
4.
Folia Med (Plovdiv) ; 62(3): 605-609, 2020 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-33009750

RESUMO

We present the case of a patient with vaginal mucosal melanoma who underwent complete remission after immunotherapy and '0-7-21' radiotherapy regimen (24 Gy/3 fractions/21 days). An 80-year-old woman had a biopsy of a voluminous vaginal lesion and received a histological diagnosis of melanoma with angiomatoid aspects. The patient underwent immunotherapy with pembrolizumab 2 mg/kg every 3 weeks and was sent to our attention for planning radiotherapy as the extent of the lesion did not make it susceptible to surgery.Considering the concomitant administration of pembrolizumab, we chose to treat this patient with a modulated intensity radiation therapy technique delivering a hypofractionated dose of 24 Gy in 3 fractions delivered on days 0, 7, and 21. We observed a complete clinical remission of the melanoma 12 months after radiotherapy and she has been alive for 18 months with no clinical signs of local recurrence.


Assuntos
Imunoterapia , Melanoma , Radioterapia de Intensidade Modulada , Neoplasias Vaginais , Idoso de 80 Anos ou mais , Feminino , Humanos , Melanoma/diagnóstico por imagem , Melanoma/terapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Vagina/diagnóstico por imagem , Neoplasias Vaginais/diagnóstico por imagem , Neoplasias Vaginais/terapia
5.
Technol Cancer Res Treat ; 19: 1533033820904447, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32336255

RESUMO

Stereotactic body radiation therapy in patients with spine metastases maximizes local tumor control and preserves neurologic function. A novel approach could be the use of stereotactic body radiation therapy with simultaneous integrated boost delivering modality. The aim of the present study is to report our experience in the treatment of spine metastases using a frameless radiosurgery system delivering stereotactic body radiation therapy-simultaneous integrated boost technique. The primary endpoints were the pain control and the time to local progression; the secondary ones were the overall survival and toxicity. A total of 20 patients with spine metastases and 22 metastatic sites were treated in our center with stereotactic body radiation therapy-simultaneous integrated boost between December 2007 and July 2018. Stereotactic body radiation therapy-simultaneous integrated boost treatments were delivered doses of 8 to 10 Gy in 1 fraction to isodose line of 50%. The median follow-up was 35 months (range: 12-110). The median time to local progression for all patients was not reached and the actuarial 1-, 2-, and 3-years local free progression rate was 86.36%. In 17 of 20 patients, a complete pain remission was observed and 3 of 20 patients had a partial pain remission (complete pain remission + partial pain remission: 100%). The median overall survival was 38 months (range 12-83). None of the patients experienced neither radiation adverse events (grade 1-4) nor reported pain flair reaction. None of the patients included in our series experienced vertebral compression fracture. Spine radiosurgery with stereotactic body radiation therapy-simultaneous integrated boost is safe. The use of this modality in spine metastases patients provides an excellent local control.


Assuntos
Fraturas por Compressão/complicações , Manejo da Dor/métodos , Radiocirurgia/métodos , Fraturas da Coluna Vertebral/complicações , Neoplasias da Coluna Vertebral/secundário , Neoplasias da Coluna Vertebral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fracionamento da Dose de Radiação , Feminino , Fraturas por Compressão/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Fraturas da Coluna Vertebral/patologia , Neoplasias da Coluna Vertebral/mortalidade , Taxa de Sobrevida , Resultado do Tratamento
6.
Anticancer Res ; 35(9): 4949-53, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26254393

RESUMO

AIM: A retrospective analysis was performed in our two Institutions in order to evaluate the feasibility and reliability of a hypofractionated-radiotherapy regimen in the treatment of frail elderly patients with facial basal cell carcinomas (BCCs). PATIENTS AND METHODS: The records of elderly patients (age >75 years) with histologically-confirmed BCC, T1-2, treated to a total radiation dose of 25-30 Gy over 5-6 weeks, were retrospectively analyzed. RESULTS: From February 2007-December 2010, 134 ambulatory patients with 159 BCCs were treated. Their median age was 82.5 years (range=75-103). Grade 1-2 skin acute toxicities were observed in 30.6% of patients (41/134). Complete responses were observed in 157 tumors in 132 patients. At the last follow-up, June 2014, no late toxicities had been noted; three patients had local recurrent disease. CONCLUSION: Our results seem to demonstrate both the feasibility and efficacy of curative hypofractionated radiation therapy in elderly patients with BCCs unfit for daily irradiation.


Assuntos
Carcinoma Basocelular/radioterapia , Neoplasias Faciais/radioterapia , Idoso Fragilizado , Neoplasias Cutâneas/radioterapia , Idoso , Idoso de 80 Anos ou mais , Relação Dose-Resposta à Radiação , Feminino , Humanos , Linfonodos/patologia , Masculino
8.
Tumori ; 101(6): 609-13, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25983093

RESUMO

PURPOSE: To evaluate clinical results in elderly and frail patients with bladder cancer treated with curative conformal irradiation alone. METHODS: The records of ambulatory frail elderly patients, age >80 years, Charlson Comorbidity Index (CCI) >5, with invasive bladder cancer, were retrospectively analyzed. The patients were irradiated with curative intent. Acute and late toxicities were evaluated. RESULTS: A total of 27 ambulatory patients were treated. Median age was 84.5 years and a median CCI of 6.5 was recorded. Median delivered radiation dose was 64 Gy. All patients completed the planned treatment. Grade 1-2 gastrointestinal (GI) and genitourinary (GU) toxicities were observed in 55.5% of patients (15/27). At the last follow-up, no late G3+ toxicities have been observed, with G1-2 toxicities reported in 11.1% of patients (3/27). Higher values of CCI were associated with higher acute GU/GI toxicities; there was a correlation between CCI and acute GU toxicity (r = 0.43, p = 0.027). The mean survival time was 23.5 months (95% confidence interval 20.9-26.1) and no median was reached. Locoregional disease-free events and metastasis-free survival showed a 2-year actuarial rate of 90% and 87%, respectively, with an actuarial 2-year overall survival of 84.5%. CONCLUSIONS: Our results demonstrate safety and feasibility of curative radiation therapy in very elderly and frail patients with bladder cancer using 3D conformal radiation therapy.


Assuntos
Idoso Fragilizado , Neoplasias Musculares/radioterapia , Radioterapia Conformacional , Neoplasias da Bexiga Urinária/patologia , Neoplasias da Bexiga Urinária/radioterapia , Análise Atuarial , Idoso de 80 Anos ou mais , Comorbidade , Intervalo Livre de Doença , Estudos de Viabilidade , Feminino , Trato Gastrointestinal/efeitos da radiação , Humanos , Imageamento Tridimensional , Masculino , Registros Médicos , Neoplasias Musculares/patologia , Invasividade Neoplásica , Estadiamento de Neoplasias , Lesões por Radiação/etiologia , Dosagem Radioterapêutica , Radioterapia Conformacional/efeitos adversos , Estudos Retrospectivos , Análise de Sobrevida , Resultado do Tratamento , Sistema Urogenital/efeitos da radiação
9.
Eur Radiol ; 23(8): 2288-95, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23479222

RESUMO

PURPOSE: To compare the diagnostic accuracy of iodine quantification and standard enhancement measurements in distinguishing enhancing from nonenhancing renal masses. MATERIALS AND METHODS: The Institutional Review Board approved this retrospective study conducted from data found in institutional patient databases and archives. Seventy-two renal masses were characterised as enhancing or nonenhancing using standard enhancement measurements (in HU) and iodine quantification (in mg/ml). Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of standard enhancement measurements and iodine quantification were calculated from χ (2) tests of contingency with histopathology or imaging follow-up as the reference standard. Difference in accuracy was assessed by means of McNemar analysis. RESULTS: Sensitivity, specificity, PPV, NPV and diagnostic accuracy for standard enhancement measurements and iodine quantification were 77.7 %, 100 %, 100 %, 81.8 %, 89 % and 100 %, 94.4 %, 94.7, 100 % and 97 %, respectively. The McNemar analysis showed that the accuracy of iodine quantification was significantly better (P < 0.001) than that of standard enhancement measurements. CONCLUSION: Compared with standard enhancement measurements, whole-tumour iodine quantification is more accurate in distinguishing enhancing from nonenhancing renal masses. KEY POINTS: • Enhancement of renal lesions is important when differentiating benign from malignant tumours. • Dual-energy CT offers measurement of iodine uptake rather than mere enhancement values. • Whole-tumour iodine quantification seems more accurate than standard CT enhancement measurements.


Assuntos
Iodo , Neoplasias Renais/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
10.
AJR Am J Roentgenol ; 199(5): 1026-34, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23096175

RESUMO

OBJECTIVE: The purpose of this study was to assess the value of dual-source dual-energy CT in the evaluation of complex cystic renal masses. SUBJECTS AND METHODS: Seventy patients underwent contrast-enhanced dual-energy CT that included true unenhanced images acquired in single-energy mode, corticomedullary phase images acquired in dual-energy mode, and nephrographic phase images acquired in single-energy mode. Virtual unenhanced, blended weighted-average, and color-coded iodine overlay images were reconstructed. The acceptance level and image quality of virtual and true unenhanced images were evaluated. Contrast enhancement on both true unenhanced or blended weighted-average images and color-coded iodine overlay images was evaluated with both calculation in regions of interest and use of confidence level scales. Radiation dose parameters were estimated. RESULTS: Virtual unenhanced images of 70 lesions (97.2%) and true unenhanced images of 72 lesions (100%) were judged acceptable (p = 0.5). The mean quality score of virtual unenhanced images was 2.0 ± 0.7 and of true unenhanced images was 1.5 ± 0.5 (p < 0.001). Mean contrast enhancement measured on true unenhanced and blended weighted-average images was 45.9 ± 15.9 HU (range, 21-78 HU) and on color-coded iodine overlay images was 47.3 ± 16.8 HU (range, 22-75 HU) with no significant differences. Enhancement was excluded on color-coded iodine overlay images with a significantly (p < 0.03) higher level of confidence than it was on true unenhanced and blended weighted-average images. The mean dose reduction with use of a combined dual- and single-energy dual-phase CT protocol was 29.1% ± 11.9% (p < 0.001). CONCLUSION: Dual-source dual-energy CT is a reliable imaging technique in the evaluation of complex cystic renal masses. True unenhanced images can be replaced by virtual unenhanced images with considerable radiation dose reduction. The color-coded iodine overlay technique is a useful tool for both excluding and identifying endocystic enhancement.


Assuntos
Doenças Renais Císticas/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
11.
Acad Radiol ; 19(10): 1186-93, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22818789

RESUMO

RATIONAL AND OBJECTIVES: To investigate whether a nonlinear-blending algorithm improves tumor conspicuity and image quality in the evaluation of renal masses at dual-energy computed tomography (DECT) during nephrographic phase of enhancement. MATERIALS AND METHODS: The Institutional Review Board approved this retrospective study from archival material from patients consenting to the use of medical records for research purposes. A retrospective review of contrast-enhanced abdominal DECT scans in 45 patients (mean age, 59.5 years; range, 24-84 years) was performed. DECT data were reconstructed using nonlinear and linear blending. A region of interest was located within tumors and adjacent normal parenchyma; attenuation differences and contrast-to-noise ratios (CNRs) were calculated for renal masses on nonlinear- and linear-blended images. The two datasets were subjectively compared in terms of tumor detection and image quality. An exact Wilcoxon's matched pairs signed rank and marginal homogeneity tests were used to test whether differences in attenuation, CNR, and subjective assessment were greater using nonlinear blending. RESULTS: The mean difference in attenuation for renal masses and adjacent portion of renal parenchyma was 138.4 Hounsfield units ± 28.9 SD using nonlinear blending, and 121.6 HU ± 18.0 SD using linear blending (P < .001). Mean CNR was 12.6 ± 2.5 SD using nonlinear blending, and 9.6 ± 2.2 SD using 0.3 linear-blended (P < .001). No significant difference in tumor detection was observed between the two algorithms. Image quality was significantly better (P < .001) using nonlinear blending. CONCLUSION: Compared with standard linear blending, nonlinear-blending algorithm improves tumor conspicuity and image quality in renal masses at DECT evaluation during nephrographic phase of enhancement.


Assuntos
Neoplasias Renais/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Simulação por Computador , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Dinâmica não Linear , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
12.
Skeletal Radiol ; 41(8): 955-61, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22069033

RESUMO

PURPOSE: To examine the usefulness of dual-echo dual-flip angle spoiled gradient recalled (SPGR) magnetic resonance imaging (MRI) technique in quantifying muscle fat fraction (MFF) of pelvic and thighs muscles as a marker of disease severity in boys with Duchenne muscular dystrophy (DMD), by correlating MFF calculation with clinical assessments. We also tried to identify characteristic patterns of disease distribution. MATERIALS AND METHODS: Twenty consecutive boys (mean age, 8.6 years ± 2.3 [standard deviation, SD]; age range, 5-15 years; median age, 9 years;) with DMD were evaluated using a dual-echo dual-flip angle SPGR MRI technique, calculating muscle fat fraction (MFF) of eight muscles in the pelvic girdle and thigh (gluteus maximus, adductor magnus, rectus femoris, vastus lateralis, vastus medialis, biceps femoris, semitendinosus, and gracilis). Color-coded parametric maps of MFF were also obtained. A neurologist who was blinded to the MRI findings performed the clinical assessments (patient age, Medical Research Council score, timed Gower score, time to run 10 m). The relationships between mean MFF and clinical assessments were investigated using Spearman's rho coefficient. Positive and negative correlations were evaluated and considered significant if the P value was < 0.05. RESULTS: The highest mean MFF was found in the gluteus maximus (mean, 46.3 % ± 24.5 SD), whereas the lowest was found in the gracilis muscle (mean, 2.7 % ± 4.7 SD). Mean MFF of the gluteus maximus was significantly higher than that of the other muscles (P < 0.01), except for the adductor magnus and biceps muscles. A significant positive correlation was found between the mean MFF of all muscles and the patients age (20 patients; P < 0.005), Medical Research Council score (19 patients; P < 0.001), timed Gower score (17 patients; P < 0.03), and time to run 10 m (20 patients; P < 0.001). A positive correlation was also found between the mean MFF of the gluteus maximus muscle and the timed Gower score. Color-coded maps provided an efficient visual assessment of muscle fat content and its heterogeneous distribution. CONCLUSION: Muscle fat fraction calculation and mapping using the dual-echo dual-flip angle SPGR MRI technique are useful markers of disease severity and permit patterns of disease distribution to be identified in patients with DMD.


Assuntos
Tecido Adiposo/patologia , Adiposidade , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/patologia , Distrofia Muscular de Duchenne/diagnóstico , Adolescente , Criança , Feminino , Humanos , Masculino , Pelve , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Estatística como Assunto , Coxa da Perna
13.
Skeletal Radiol ; 41(5): 515-24, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-21611841

RESUMO

PURPOSE: To describe the magnetic resonance imaging (MRI) pattern of muscle involvement and disease progression in five patients with late-onset Charcot-Marie-Tooth (CMT) disease type 2 F, due to a previously unknown mutation. MATERIALS AND METHODS: Five patients (three males, two females) underwent MRI of the lower limbs to define the pattern of muscle involvement and evaluate the muscle fat fraction (MFF) of residual thigh muscle with gradient-echo (GRE) dual-echo dual-flip angle technique. Evaluation of fatty infiltration both by visual inspection and MFF calculation was performed. RESULTS: A proximal-to-distal gradient of muscle involvement was depicted in male patients with extensive muscle wasting of lower legs, less severe impairment of distal thigh muscles, and sparing of proximal thigh muscles. A peculiar phenotype finding was that no or only slight muscle abnormalities could be found in the two female patients. CONCLUSION: We described the pattern of muscle involvement and disease progression in a family with CMT disease type 2 F. GRE dual-echo dual-flip angle MRI technique is a valuable technique to obtain a rapid quantification of MFF.


Assuntos
Tecido Adiposo/patologia , Doença de Charcot-Marie-Tooth/patologia , Músculo Esquelético/patologia , Atrofia Muscular/patologia , Idoso , Doença de Charcot-Marie-Tooth/genética , Progressão da Doença , Feminino , Proteínas de Choque Térmico HSP27/genética , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Atrofia Muscular/genética , Mutação , Linhagem , Coxa da Perna
14.
Radiat Oncol ; 6: 162, 2011 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-22108341

RESUMO

BACKGROUND: to evaluate activity and toxicity of a sequential treatment in advanced, non metastatic, mostly unresectable, head and neck squamous cell carcinoma. METHODS: Patients with loco-regionally advanced or unresectable, head and neck cancer, were prospectively treated with 3 courses of induction chemotherapy followed by concurrent chemoradiation. Induction chemotherapy consisted of paclitaxel 175 mg/m2 day 1 and cisplatin 75 mg/m2 day 2, given every 3 weeks, to a total of three courses. Curative radiotherapy started 4 weeks after the last cycle of chemotherapy with the goal of delivering a total dose ≥ 66 Gy. During RT weekly paclitaxel (40 mg/m2) was administered. RESULTS: The trial accrued 43 patients from January 1999 to December 2002. All patients received 3 courses of induction chemotherapy and the planned dose of radiotherapy. Thirty-eight patients were able to tolerate weekly paclitaxel during irradiation at least for 4 courses. After induction therapy there were 32 overall responses, 74.4% (23 partial and 9 complete); at completion of concomitant treatment overall responses were 42, 97.7% (20 partial and 22 complete). Median time to treatment failure was 20 months and the disease progression rate at 3 and 5 years was 33% and 23%, respectively. The median overall survival time was 24 months and 3 and 5 years overall survival rates were 37% and 26%, respectively. The major toxicity was mucositis. CONCLUSIONS: This combined treatment was found to be feasible and active in advanced or unresectable, head and neck squamous cell carcinoma patients. Long-term results observed in this trial encourage to consider this approach in further investigation using newer radiation delivering technique and new molecularly agents.


Assuntos
Carcinoma de Células Escamosas/terapia , Quimiorradioterapia/métodos , Neoplasias de Cabeça e Pescoço/terapia , Quimioterapia de Indução/métodos , Adulto , Idoso , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carcinoma de Células Escamosas/patologia , Cisplatino/administração & dosagem , Feminino , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Paclitaxel/administração & dosagem , Estudos Prospectivos
15.
Radiology ; 259(2): 487-94, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21324839

RESUMO

PURPOSE: To prospectively evaluate the muscle fat fraction (MFF) measured with dual-echo dual-flip-angle spoiled gradient-recalled acquisition in the steady state (SPGR) magnetic resonance (MR) imaging technique by using muscle biopsy as the reference standard. MATERIALS AND METHODS: After ethics approval, written informed consent from all patients was obtained. Twenty-seven consecutive patients, evaluated at the Neuromuscular Disorders Center with a possible diagnosis of neuromuscular disorder, were prospectively studied with MR imaging of the lower extremities to quantify muscle fatty infiltration by means of MFF calculation. Spin-density- and T1-weighted fast SPGR in-phase and opposed-phase dual-echo sequences were performed, respectively, with 20° and 80° flip angles. Round regions of interest were drawn by consensus on selected MR sections corresponding to anticipated biopsy sites. These were marked on the patient's skin with a pen by using the infrared spider light of the system, and subsequent muscle biopsy was performed. MR images with regions of interest were stored on a secondary console where the MFF calculation was performed by another radiologist blinded to the biopsy results. MFFs calculated with dual-echo dual-flip-angle SPGR MR imaging and biopsy were compared by using a paired t test, Pearson correlation coefficient, and Bland-Altman plots. P value of < .05 was considered to indicate a statistically significant difference. RESULTS: The mean MFFs obtained with dual-echo dual-flip-angle SPGR MR imaging and biopsy were 20.3% (range, 1.7%-45.1%) and 20.6% (range, 3%-46.1%), respectively. The mean difference, standard deviation of the difference, and t value were -0.3, 1.3, and -1.3 (P > .2), respectively. The Pearson correlation coefficient was 0.995; with the Bland-Altman method, all data points were within the ± 2 SDs limits of agreement. CONCLUSION: The results show that dual-echo dual-flip-angle SPGR MR imaging technique provides reliable calculation of MFF, consistent with biopsy measurements.


Assuntos
Tecido Adiposo/patologia , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/patologia , Doenças Neuromusculares/diagnóstico , Adolescente , Adulto , Idoso , Biópsia , Criança , Estudos de Viabilidade , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Atrofia Muscular/patologia , Estudos Prospectivos
16.
Med Phys ; 37(8): 4249-56, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20879585

RESUMO

PURPOSE: The objective of this study is to develop a method to calculate the relative dose increase when a computerized tomography scan (CT) is carried out after administration of iodinated contrast medium, with respect to the same CT scan in absence of contrast medium. METHODS: A Monte Carlo simulation in GEANT4 of anthropomorphic neck and abdomen phantoms exposed to a simplified model of CT scanner was set up in order to calculate the increase of dose to thyroid, liver, spleen, kidneys, and pancreas as a function of the quantity of iodine accumulated; a series of experimental measurements of Hounsfield unit (HU) increment for known concentrations of iodinated contrast medium was carried out on a Siemens Sensation 16 CT scanner in order to obtain a relationship between the increment in HU and the relative dose increase in the organs studied. The authors applied such a method to calculate the average dose increase in three patients who underwent standard CT protocols consisting of one native scan in absence of contrast, followed by a contrast-enhanced scan in venous phase. RESULTS: The authors validated their GEANT4 Monte Carlo simulation by comparing the resulting dose increases for iodine solutions in water with the ones presented in literature and with their experimental data obtained through a Roentgen therapy unit. The relative dose increases as a function of the iodine mass fraction accumulated and as a function of the Hounsfield unit increment between the contrast-enhanced scan and the native scan are presented. The data shown for the three patients exhibit an average relative dose increase between 22% for liver and 74% for kidneys; also, spleen (34%), pancreas (28%), and thyroid (48%) show a remarkable average increase. CONCLUSIONS: The method developed allows a simple evaluation of the dose increase when iodinated contrast medium is used in CT scans, basing on the increment in Hounsfield units observed on the patients' organs. Since many clinical protocols employ multiple scans at different circulatory phases after administration of contrast medium, such a method can be useful to evaluate the total dose to the patient, also in view of potential clinical protocol optimizations.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Radioisótopos do Iodo/análise , Radioisótopos do Iodo/farmacocinética , Modelos Biológicos , Contagem Corporal Total/métodos , Simulação por Computador , Humanos , Taxa de Depuração Metabólica , Modelos Estatísticos , Especificidade de Órgãos , Doses de Radiação , Compostos Radiofarmacêuticos/análise , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
17.
Abdom Imaging ; 35(2): 241-5, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19194642

RESUMO

BACKGROUND: Within the term "pseudotumors" are grouped some renal anatomic variations that may simulate a focal renal lesion at ultrasonography. Our purpose was to assess the accuracy of contrast-enhanced ultrasonography (CEUS) using a second-generation contrast agent in the diagnosis of renal pseudotumors. METHODS: We retrospectively retrieved CEUS examinations performed in 24 patients for characterization of suspected renal pseudotumor, in which conventional and power Doppler US study had been unable to confidently exclude a neoplasm. The considered criterion to define the diagnosis of renal pseudotumor was the demonstration of the same perfusion and reperfusion after microbubble breakage in both pseudotumor and surrounding parenchyma during early and late corticomedullary phase. In all patients, multiphase CT or dynamic MRI was available, representing a standard of reference for this study. In cases of CT or MRI diagnosis of renal lesion, final diagnoses were obtained with percutaneous renal biopsy or with surgery. RESULTS: Contrast-enhanced ultrasonography diagnosis was concordant with MR or CT images in all cases. CONCLUSION: In our experience CEUS shows complete concordance with CT and MRI in the characterization of all 24 pseudotumors considered dubious at conventional and power Doppler US. The appropriate use of CEUS can reduce the need for contrast-enhanced CT or dynamic MRI in this item.


Assuntos
Rim/anormalidades , Rim/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Compostos Heterocíclicos , Humanos , Iohexol/análogos & derivados , Neoplasias Renais/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
18.
Radiology ; 243(1): 158-65, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17392251

RESUMO

PURPOSE: To prospectively compare contrast material-enhanced ultrasonography (US) with computed tomography (CT) in the classification of complex cystic renal masses with the Bosniak system. MATERIALS AND METHODS: Ethics committee approval and written informed consent were obtained. Forty patients (17 women, 23 men; age range, 31-77 years) with 44 complex cystic renal masses detected with conventional US were prospectively examined by using second-harmonic US with a second-generation contrast agent and multiphasic helical CT. Thirty-six patients had one lesion, and four patients had two lesions. Surgical resection in nine patients and imaging follow-up in 31 patients were used to determine the outcome. RESULTS: On contrast-enhanced US images, masses were classified as Bosniak category II (n = 18), IIF (ie, lesions were classified as category II and follow-up was needed) (n = 16), III (n = 7), or IV (n = 3) lesions. On CT images, masses were classified as Bosniak category II (n = 24), IIF (n = 10), III (n = 7), or IV (n = 3) lesions. Interobserver agreement was high (kappa = 0.86, P < .001) for classification with US. Complete concordance between the readers was found for classification with CT. Complete concordance between contrast-enhanced US and CT was observed in the differentiation of surgical and nonsurgical complex cysts. Complete concordance among the three readers in the assessment of vascularity with contrast-enhanced US was found. Interobserver agreement in the evaluation of enhancement on CT images was high (kappa = 0.88, P < .001). Concordance between contrast-enhanced US and CT in the evaluation of vascularization was high (kappa = 0.77, P < .001). CONCLUSION: The study data suggest that contrast-enhanced second-harmonic US is appropriate for renal cyst classification with the Bosniak system.


Assuntos
Meios de Contraste , Cistos/diagnóstico por imagem , Nefropatias/diagnóstico por imagem , Adulto , Idoso , Carcinoma de Células Renais/diagnóstico por imagem , Feminino , Humanos , Neoplasias Renais/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Ultrassonografia/métodos
19.
Int J Radiat Oncol Biol Phys ; 65(1): 25-32, 2006 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-16446058

RESUMO

PURPOSE: To evaluate the role of chemotherapy combined with curative radiotherapy in breast cancer patients who presented with recurrent ipsilateral supraclavicular lymph node metastases (ISLM) without "nonregional disease," we designed an observational study performed prospectively. PATIENTS AND METHODS: Forty-four consecutive patients with ISLM from breast cancer as part of recurrent regional disease without distant metastases were included in this study. All patients received chemotherapy with doxorubicin-based schema or paclitaxel for six courses and curative radiotherapy (60 Gy/30 fractions of 2 Gy/5 days a week). An "involved field" radiation was delivered during the interval between the third and fourth chemotherapy course; hormonal therapy was given based on receptor status. RESULTS: The rate of overall clinical response after chemotherapy and radiotherapy was 94.9%. Median time to progression and overall survival were 28 and 40 months, respectively; the 5-year actuarial overall survival and disease-free survival rates were 35% (95% confidence interval, 19-51) and 20% (95% confidence interval, 6-34), respectively. CONCLUSION: A curative course of intravenous chemotherapy and radical irradiation is feasible in patients with ISLM. All patients presenting recurrence in supraclavicular nodes should be treated with definitive locoregional treatments and systemic therapy because the outcomes are better than might be historically assumed.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/radioterapia , Linfonodos , Recidiva Local de Neoplasia/tratamento farmacológico , Recidiva Local de Neoplasia/radioterapia , Adulto , Idoso , Análise de Variância , Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/patologia , Clavícula , Terapia Combinada/métodos , Ciclofosfamida/administração & dosagem , Doxorrubicina/administração & dosagem , Feminino , Fluoruracila/administração & dosagem , Humanos , Metástase Linfática , Pessoa de Meia-Idade , Estadiamento de Neoplasias/métodos , Paclitaxel/administração & dosagem , Estudos Prospectivos , Dosagem Radioterapêutica , Análise de Sobrevida
20.
J Magn Reson Imaging ; 20(2): 264-71, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15269952

RESUMO

PURPOSE: To determine whether magnetic resonance urography (MRU), obtained before helical computed tomography (CT) in patients with acute renal colic, can help delimit the obstructed area to be subsequently examined by a targeted CT scan, thus reducing the dose of radiation. MATERIALS AND METHODS: Patients (51) with symptoms of acute renal colic underwent MRU and a total urinary tract helical CT. CT images from the 5 cm below the level of ureteral obstruction as demonstrated by MRU were selected out. Combined interpretation of MRU and selected CT images constituted protocol A. Protocol B consisted of the entire unenhanced helical CT of the urinary tract. The two protocols were compared regarding the following points: 1) sensitivity in diagnosing the presence of obstructing urinary stones, and 2) the delivered radiation dose. RESULTS: Protocol A and protocol B had, respectively, 98% and 100% sensitivity in demonstrating ureteral stone as a cause of renal colic. Estimated average dose calculated from phantom study was 0.52 mSv for protocol A and 2.83 mSv for protocol B. Therefore, the effective radiation dose was 5.4 times lower in protocol A compared to protocol B. CONCLUSION: Combined MRU and short helical CT has a high sensitivity in detecting ureteral calculi with a reduced radiation dose.


Assuntos
Cálculos Renais/diagnóstico , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Urografia/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Cálculos Renais/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...